DLE DC4 fn d1...d7 (Specification of fn = 8)
[Function] Buffer clear
[Code] <10>H<14>H<fn><d1> <d7>
[Range] fn=8, d1=1, d2=3, d3=20, d4=1, d5=6, d6=2, d7=8
[Outline] [The specification which is common to the model]
• Erases all data in receiving buffer or print buffer.
• Sends the following 3-byte data group.
Hex.
Decimal
No. of Data
Header
37H
55
1 byte
Identifier
25H
37
1 byte
NULL
00H
0
1 byte
• Enters the state of selecting STANDARD MODE.
[Caution] [The specification which is common to the model]
• When receiving a code row coinciding with the code configuring this command, the
same operation as this command takes place and attention by the user is required.
Example: When corresponding code row is present in bit image data.
• This command must not be used between other command code rows.
Example: This command is used in the bit image data.
• This command is ignored under the following conditions.
• During sending block data