T-Series Traffic Director Installation, Configuration and Administration Guide 1-7
Product Capabilities
T1000 Technical Specifications
The T1000 software offers the following standard and optional feature specifications.
Layer 4 to 7 Traffic Management
• Algorithms: Load-Sensitive Traffic Distribution, Round Robin, Least Packets, Least
Bandwidth, Least Connections, Response Time, Hashing (URL, Domain, Source IP,
Destination IP, and Custom ID), SNMP-provided metric
• Session persistence: Source IP, cookie, server, group, SSL session, Token-based,
JSESSIONID.
• Server monitoring: Ping, TCP, URL, ECV, scriptable health checks, Dynamic Server
Response Time.
• Link load balancing.
Layer 7 Content Switching
Policies: URL, URL Query, URL Wildcard, Domain, Source/Destination IP, HTTP Header,
Custom, HTTP and TCP Payload Values, UDP.
Application Security
• DoS attack defense: Continue service to legitimate users while protecting against
attacks such as: SYN Flood, HTTP DoS and Ping of Death. ICMP and UDP rate
control. HTTP and TCP session rate control.
• DNS: DNS proxy and caching. Authoritative DNS. DNS Signing.
DC Power Specification
• -56.7 to -40
VDC
• 18A-9A
• 450w, 1536
BTU/Hr
• -56.7 to -40
VDC
• 18A-9A
• 850w, 2219
BTU/Hr
• -56.7 to -40
VDC
• TBD
• TBD
Height 1U 2U 2U
Width Standard Rack
Depth 24 in 28 in 28 in
Weight 32 lbs (14.5 kg) 49 lbs (22.2 kg) 49 lbs (22.2 kg)
Operating Temperature 0-40°C
Allowed relative humidity 5%-95%, non-condensing
Safety certification UL, TUV-C
Electromagnetic FCC (Part 15 Class A),DoC, CE, VCCI, CNS, AN/NES
Hazardous Substances RoHS
Specification T1010 T1100 T1200