Page 20 WS1CI & WS1.25CI Manual
Step 7F – Set Volume Capacity using the or button. If value is set to:
• “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings Step 3I);
or
• as a number (allowable range 0.020 to 325.10 M
3
) regeneration initiation will be abased off the value
specifi ed. Increment increase is 0.02 for the range 0.02 to 2.000, 0.05 for the range of 1.000 to 10.00
and 0.10 for the range 20.00 to 325.10.
See Table 9 for more detail. Press NEXT to go to Step 8F. Press REGEN to return to previous step.
Step 8F – Set Regeneration Time Options using the or button. If value is set to:
• “NORMAL” means regeneration will occur at the preset time;
• “on O” means regeneration will occur immediately when the volume capacity reaches 0 (zero); or
• “NORMAL + on 0” means regeneration will occur at one of the following:
— the preset time when the volume capacity falls below the reserve or the specifi ed number of days
between regenerations is reached whichever comes fi rst;
or
— immediately after 10 minutes of no water usage when the volume capacity reaches 0 (zero).
See Table 9 for more detail. Press NEXT to exit OEM Filter System Setup. Press REGEN to return to
previous step.
STEP 7F
STEP 8F
ß
RETURN TO
NORMAL MODE
Gallons
Capacity
Regeneration
Time Option
Day
Override
Result
oFF NORMAL
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specifi ed
number of days between regenerations is reached.
Any
number
NORMAL oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0.
Any
number
NORMAL
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0 or the specifi ed number of days between regenerations is
reached.
Any
number
On O oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration
will always occur on 0.
Any
number
NORMAL on 0
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specifi ed
number of days between regenerations is reached or regeneration occurs
after 10 minutes of no water usage when gallon capacity reaches 0.
Table 9
Filter Setting Options

Other manuals for Clack WS1CI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clack WS1CI and is the answer not in the manual?

Clack WS1CI Specifications

General IconGeneral
BrandClack
ModelWS1CI
CategoryControl Unit
LanguageEnglish

Related product manuals