WS1CI & WS1.25CI Manual Page 21
STEP 1I - Press NEXT and simultaneously for 3 seconds.
STEP 1I
STEP 2I
STEP 3I
STEP 5I
ß
STEP 6I
RETURN TO
NORMAL MODE
STEP 2I – Hardness: Set the amount of infl uent hardness
using the or buttons. This display will show “–nA–” if
“FILTER” is selected in Step 2F OR if “-nA-” was selected in
Step 2CS OR if off or a number was selected in Step 8S. Press
NEXT to go to step 3I. Press REGEN to exit Installer Display
Settings.
STEP 3I – Hardness 2: If using a mixing valve, set the amount of effl uent hardness using the or
buttons. Range of available values may vary depending on system capacity selected and hardness selected
in Step 2I. This display will show “-nA-” if “FILTER” is selected in Step 2F OR if -nA- was selected in
Step 2CS OR if off or a number was selected in Step 8S. Press NEXT to go to Step 4I. Press REGEN to
exit Installer Display Settings.
STEP 4I – Day Override: When volume capacity is set to off, sets the number of days between
regenerations. When volume capacity is set to AUTO or to a number, sets the maximum number of days
between regenerations. If value set to “oFF” regeneration initiation is based solely on volume used. If
value is set as a number (allowable range from 1 to 28) a regeneration initiation will be called for on that
day even if suffi cient volume of water were not used to call for a regeneration. Set Day Override using
or buttons:
number of days between regeneration (1 to 28); or
“oFF”.
See Table 8 for more detail on softener setup and Table 9 for more detail on fi lter setup. Press NEXT to go
to step 5I. Press REGEN to return to previous step.
STEP 5I – Next Regeneration Time (hour): Set the hour of day for regeneration using or
buttons. The default time is 2:00. This display will show “REGEN on 0 L” if “on 0” is selected in Set
Regeneration Time Option in OEM Softener System Setup or OEM Filter System Setup. Press NEXT to
go to step 6I. Press REGEN to return to previous step.
STEP 6I – Next Regeneration Time (minutes): Set the minutes of day for regeneration using or
buttons. This display will not be shown if “on 0” is selected in Set Regeneration Time Option in OEM
Softener System Setup or OEM Filter System Setup. Press NEXT to exit Installer Display Settings. Press
REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds.
The system will begin to regenerate immediately. The control valve may be stepped through the various
regeneration cycles by pressing the “REGEN” button.
STEP 4I
Allowable range may
vary depending on
system capacity
selected.
Units
Allowable
Range
PPM 1-2500
FH 1-250
dH 1-150
Installer Display Settings