Page 22 WS1CI & WS1.25CI Manual
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with low water
usage is when a household is asleep. If there is a demand for water when the system is regenerating,
untreated water will be used.
When the system begins to regenerate, the display will change to include information about the step of the regeneration process and
the time remaining for that step to be completed. The system runs through the steps automatically and will reset itself to provide
treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner than when the
system calls for it, usually referred to as manual regeneration. There may be
a period of heavy water usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time,
when the regeneration time option is set to “NORMAL” or “NORMAL + on
0”, press and release “REGEN”. The words “REGEN TODAY” will fl ash on
the display to indicate that the system will regenerate at the preset delayed regeneration time. If you pressed the “REGEN” button in
error, pressing the button again will cancel the request. Note: If the regeneration time option is set to “on 0” there is no set delayed
regeneration time so “REGEN TODAY” will not activate if “REGEN” button is pressed.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, fi ll with salt and wait at least two hours before regenerating.
➟
➟
➟
or
➟
➟
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
➟
General Operation
When the system is operating, one of three displays may be
shown. Pressing NEXT will alternate between the displays. One
of the displays is always the current time of day. The second
display is one of the following: days remaining or volume
remaining. Days remaining is the number of days left before the
system goes through a regeneration cycle. Capacity remaining
is the cubic meters that will be treated before the system goes
through a regeneration cycle. The third display shows the Kg of
salt remaining or fl ashes “SALT” fi ll when the calculated Kg of
salt falls below a safety level. The third display will not appear if
the valve is set up as a fi lter or if the Set Low Salt Warning is set
to off (see last step in OEM Softener System Setup). The user can
scroll between the displays as desired.
If the system has called for a regeneration that will occur at the
preset time of regeneration, the words REGEN TODAY will
appear on the display.
If a water meter is installed, the word “Softening” or “Filtering”
fl ashes on the display when water is being treated (i.e. water is
fl owing through the system).
➟
➟
or
➟
User Display Settings