23
- If reporting to all the programmed groups failed in a reporting
cycle, Mobile Lite will wait for 5 minutes. After 5 minutes,
Mobile Lite will retry as it starts another reporting cycle. It will
continue retrying until recognizing at least one successful
report.
Example 1, if Groups 1 and 3 are programmed for Emergency
reports, and assuming NO successful report:
Group 1 > Group 3 > Wait 5 minutes > Group 1 > Group 3 > Wait 5
minutes > Group 1 > Group 3 > Wait 5 minutes > Group 1 > Group
3 > Wait 5 minutes > Continues Reporting
Example 2, if Groups 1 and 3 are programmed for Emergency
reports, and assuming NO successful report until Group 1 is
successful after several retries:
Group 1 > Group 3 > Wait 5 minutes > Group 1 > Group 3 > Wait 5
minutes > Group 1 (Success!) > Group 3 > Stops reporting whether
Group 3 succeeded or not.
Status Events:
Mobile Lite will only go through one reporting cycle for Status reports.
For example, if Groups 1 and 3 are programmed for Status reports:
Group 1 > Group 3 > Stops reporting whether Groups 1 and 3
succeeded or not
SMS Report text format
Below are the SMS Text messages sent to user according to the condition
of the Mobile Lite and the Amplifier Base.
SMS text table:
Mobile Lite Condition
SMS Text format
Low battery status
Mobile Lite Low Battery
Battery voltage restored
Mobile Lite Battery Restored
Wakes up time
Mobile Lite Periodic Test
Weak Signal strength from the Local
Base Station
Mobile Lite Weak Signal Strength
GPS signal lost
Mobile Lite GPS Signal Failure
Carrier leaves GeoFence area
Mobile Lite has exit GeoFence Area
Carrier enters GeoFence area
Mobile Lite has entered GeoFence
Area
Charging Mobile lite in the Amplifier
Mobile Lite Charging