sequence is one reporting cycle.
Reporting behavior depends on the event type:
Emergency Events:
- When reporting to the first group is successful, Mobile Lite will
still report to the next group until all groups have been tried.
For example, Groups 1 and 3 are assigned to Emergency
Events:
If Group 1 is successful, Mobile Lite will still report to Group 3.
If reporting to Group 3 is successful, Mobile Lite will terminate
reporting.
If reporting to Group 3 is unsuccessful (going through all the
Report Index within the group for 5 times), Mobile Lite will also
terminate reporting.
- When reporting to the first group failed (going through all the
Report Index within the group for 5 times), Mobile Lite will start
reporting to the next group. When reporting to the second
group succeeded, Mobile Lite will terminate reporting.
- If reporting to all the programmed groups failed in a reporting
cycle, Mobile Lite will wait for 5 minutes. After 5 minutes,
Mobile Lite will retry as it starts another reporting cycle. It will
continue retrying until recognizing at least one successful
report.
Example 1, if Groups 1 and 3 are programmed for Emergency
reports, and assuming NO successful report:
Group 1 > Group 3 > Wait 5 minutes > Group 1 > Group 3 >
Wait 5 minutes > Group 1 > Group 3 > Wait 5 minutes > Group
1 > Group 3 > Wait 5 minutes > Continues Reporting
Example 2, if Groups 1 and 3 are programmed for Emergency
reports, and assuming NO successful report until Group 1 is
successful after several retry:
Group 1 > Group 3 > Wait 5 minutes > Group 1 > Group 3 >
Wait 5 minutes > Group 1 (Success!) > Group 3 > Stops
reporting whether Group 3 succeeded or not.
Status Events:
Mobile Lite will only go through one reporting cycle for Status
reports and will not retry if report failed.
For example, if Groups 1 and 3 are programmed for Status
reports: