Chapter 5: Maintenance and troubleshooting
98-140012-H Troubleshooting 122
The web interface
cannot be accessed.
The browser is configured to
use a proxy server.
For Microsoft Internet Explorer,
select Tools > Internet Options
> Connections > LAN Settings
and uncheck Use a proxy server
for your LAN.
You have entered a wrong IP
address.
Check the IP address and re-enter
it. The default IP address is
192.168.0.1
A Phone connection
cannot be established.
The interface is disabled in
the EXPLORER 710.
Enable the interface by selecting
the Phone interface icon in the
display, or
by accessing the web interface
and selecting Control panel >
Phone > Enable.
The cable is not properly
connected.
Connect the cable.
The cable type or connector
type is not correct.
For information on the correct
type of connector, refer to Phone
interface on page 137.
Incoming calls: The call type
used for the call is not
selected in the web interface.
Make sure the call type used for
calls to the EXPLORER 710 is
selected in the web interface.
Access the web interface and
select Control panel > Phone.
Then select the call type for
incoming calls.
Problem Possible cause Remedy