Setting up and operating the BUC system
70 Block Up Converter Systems 6700/6900 series User Guide
Set on line Sets the on-line or off-line
state of the BUC in a warm
standby or hot standby
redundant system, that is,
SRM1 or SRM2 has been
set.
SOLn n = 0, forces the selected
BUC off line
n = 1, forces the selected
BUC on line
NOTE
If a BUC is forced
off line when the
alternative BUC in
the redundancy
system is faulty,
the redundancy
system
automatically
switches the non-
faulty BUC back
on line.
Set serial
interface
Sets the data format of the
RS422/485 and FSK serial
interfaces.
The data format for these
interfaces cannot be set
independently.
This command can only be
used on the RS232 port.
SSIr,w,
p,s,t
r = baud rate (1200, 2400,
4800, 9600, 19200)
w = word length in bits
(7 or 8)
p = parity N/n (none),
E/e (even), O/o (odd)
s = number of stop bits
(1 or 2)
t = RS422/485 bus
terminated or unterminated
(T/t, U/u)
Table 14: Set commands (cont.)
Command Function Enter... Data required