Setting up and operating the BUC system
Block Up Converter Systems 6700/6900 series User Guide 71
Set packet
protocol
Sets the packet protocol used
on the RS422/485 and FSK
serial interfaces.
The packet protocols for
these interfaces cannot be set
independently.
This command can only be
used on the RS232 port.
SPPn n = 0, ASCII protocol
n = 1, Codan protocol
n = 2, SAbus protocol
n = 3, Comstream protocol
n = 4, NDSatcom protocol
Set packet
address
Sets the packet address.
The packet address range
depends on the packet
protocol selected (see
page 71, Set packet
protocol).
For information on protocols,
contact your Codan
representative.
SADn 1
n 126, Codan
protocol
49
n 111, SAbus
protocol
1
n 31, Comstream
protocol
1
n 15, NDSatcom
protocol
Set echo Switches the echoing of
characters on or off in ASCII
protocol mode on the RS232
interface only.
Echo is always off on the
FSK and RS422/485
interfaces.
SECn n = 0, disables echoing
n = 1, enables echoing
Table 14: Set commands (cont.)
Command Function Enter... Data required