For PNP lines, the external load should be connected between the output and the negative supply voltage (0 VDC).
When connected to a 24 VDC power supply, the outputs pull up greater than 21 VDC when ON, and current flows
through the load. When the outputs are OFF, no current flows through the load.
DataMan 260 High-Speed Output Wiring
To connect to an NPN-compatible PLC input, connect Output 0, Output 1, Output 2 or Output 3 directly to the PLC input.
When enabled, the output pulls the PLC input down to less than 3 VDC.
To connect to a PNP-compatible PLC input, connect Output 0, Output 1, Output 2 or Output 3 directly to the PLC input.
When enabled, the output pulls the PLC input up to greater than 21 VDC.