Reducing DataMan Processing Requirements
The more information that you can provide to DataMan about your application, the less work – and processing time – will
be required to decode symbols.
l Only enable the symbologies that your application uses. Disabling unused symbologies reduces processing
time.
l Train codes.
l Only enable extended mode decoding if your application requires it.
Avoiding Reflections and Glare
If the DataMan is mounted perpendicular to the surface containing the code to be read, reflections from the built-in
illumination system can cause reflections and glare that may reduce decoding performance.
You can avoid this problem by mounting the reader at a 15° angle from vertical.