MACHINE PREPARATION
4. TYPE OF BATTERY (Versions B-BT)
To power the machine it is necessary to use:
liquidelectrolyte lead traction batteries;
sealed traction batteries with gas recombination or gel technology.
OTHER TYPES MUST NOT BE USED.
The batteries must meet the requirements laid out in the norms: CEI EN 60254-1:2005-12 (CEI 21-5)
+ CEI EN 60254-2:2008-06 (CEI 21-7)
Every battery consists of DIN-type elements connected in series and providing the clamps with a
power of 6 V. You are advised to use batteries with an electric capacity of 200 Ah (C5)
5. BATTERY MAINTENANCE AND DISPOSAL (B-BT versions)
For maintenance and recharging, respect the instructions provided by the battery manufacturer.
Particular attention must be paid when choosing the battery charger, if not supplied, since there are
different kinds according to the type and capacity of the battery.
Proceed as follows when the battery is dead:
1. Disconnect the quick connector and remove the solution tank.
2. Open the battery compartment and disconnect the connector.
3. Remove the battery by using suitable devices, lifting it with the provided handles.
DEAD BATTERIES ARE CLASSIFIED AS DANGEROUS WASTE AND MUST BE DELIVERED TO
THE AUTHORISED BODIES FOR CORRECT DISPOSAL.
WARNING: You are advised to always wear protective gloves, to avoid the
risk of serious injury to your hands.
WARNING: You are advised to only lift and move the batteries with lifting and
transportation means suitable for the specific weight and size
6. INSERTING/CONNECTING THE BATTERIES (B-BT versions)
The machine may be supplied with batteries and a built-in battery charger.
If batteries other than those supplied with the machine are used, have the battery charger and battery
control card configuration checked by a qualified, COMAC-trained technician.
Perform a battery charging cycle before using the machine.
The batteries must be housed in the appropriate compartment beneath the recovery tank, and must
satisfy the requisites of Standard CEI 21-5.
To insert the batteries you must:
1. Engage the machine's parking brake
2. Lower the squeegee and brush head (see the appropriate chapter)
3. Make sure the recovery tank is empty, otherwise empty it completely
4. release the hinges (1) on the handlebars.
Rotate the recovery tank as far as it will go, using the side handle (2).
ATTENTION: Before fitting the batteries, lift in the backing and connect the
traction connector.
this process must be carried out by qualified personnel. An incorrect
connection of the connector may cause problems with machine functioning.
This operation is possible for machines with traction only