Operati on l 4-45
4
Operation
NOTE: For more information concerning specific dewpoint control screens, see Control
Function Descriptions, page 4-11.
✐
Using Dewpoint Control
Your dryer is equipped with a dewpoint monitor and dewpoint control features.
You can choose to use it as a monitor only device, or to maintain a steady
dewpoint that you select with the dewpoint control. Dewpoint control will vary
the regeneration air temperature to condition the desiccant to the level necessary
to maintain the desired dewpoint.
Dewpoint Monitor
NOTE: The supervisor's password is necessary. Please refer to the “Using the Supervisor’s
Password” section on page 4-41.
From “Dryer Main Menu”, select “Setup, Other OPT” to get to the “Dryer
Setup Options Information” (screen 14, page 4-14). Proceed to screen 75 (page
4-29). “Dewpoint Monitor” must be set to “Installed” and “Dewpoint Control”
set to “Not Installed”. Screen 11 (page 4-14) will display the actual dewpoint
readout.
Dewpoint Control
NOTE: The supervisor's password is necessary. Please refer to the “Using the Supervisor’s
Password” section on page 4-41.
From “Dryer Main Menu”, select “Setup, Other OPT” to get to the “Dryer
Setup Options Information” (screen 14, page 4-14). Proceed to screen 75 (page
4-29). “Dewpoint Control” must be set to “Installed”. “Dewpoint Monitor”
can be set to “Installed” or “Not Installed”. Screen 11 (page 4-14) will display
the actual dewpoint and the dewpoint setpoint the dryer is to maintain.
✐
✐
NOTE: Dewpoint control is inactive when the dewpoint setpoint is -40° F {-40° C}
.
✐