Screen
SCREEN 1
SCREEN 2
SCREEN 3 (Default Screen)
Function
Once power is turned on, this screen is
displayed for 3 seconds. It shows
CONAIR and the dryer type on the first
line, and the control program version and
display program version on the second
line.
Once power is turned on and screen 1 is
displayed for 3 seconds, this screen is
displayed for another 3 seconds. It shows
the day of the week on the first line and
the date and time on the second line. If
this information is not correct, it can be
changed under the SETUP, DISP, DATE
TIME screen 73.
This is the DEFAULT screen. It shows
the process air temperature setpoint and
actual temperature measured at the inlet to
the drying hopper. The setpoint can be
changed by pressing the Select Category
button under the Setpoint Value. Once the
button is pressed, the setpoint will begin
to flash. The numeric keys can be used to
enter a new setpoint or the (+) or (-)
Increment / Decrement buttons can be
used to change the setpoint. Holding the
(+) or (-) buttons in will allow the
number to ramp up faster the longer the
button is held. The “ENTER” key must
be pressed to accept the new number. The
temperature setpoint range can be changed
under the
(continued)
CONAIR D100
CV2.21.00 DV2.21.00
MONDAY
07/22/03 07:59 AM
PROCESS TEMPERATURE
ACT 325°F SET 325°F
Control Function Descriptions
4
Operation
When supplied for
central drying appli-
cations, this function
is not available.
Operatio n l 4-11
NOTE: The supervisory
password is required to
change certain parameters.
Additional information about
the password can be on
Page 4-37 and under
screen 85 on page 4-31.
✐