Screen
SCREEN 3 (Default Screen)
(continued)
SCREEN 4
SCREEN 5
PROCESS TEMPERATURE
ACT 325°F SET 325°F
SETUP, PROC, PROC, PROC, PROCESS
TEMPERATURE RANGE screen 39. The
display will return to the default screen
from anyplace in the menu structure (with
the exception of the AUTOTUNE screens)
if nothing is done after 10 minutes.
Pressing the “MENU” button from any
place in the menu structure will return you
to the default screen.
Shows the regeneration air setpoint and
actual temperature. The setpoint can be
changed with the correct password.
NOTE: Lowering the regeneration setpoint
decreases the capacity of the dryer and
normally is not recommended. Use the
dewpoint control function instead.
Shows the actual return air temperature
measured at the inlet to the process
blower. If the optional aftercooler flow
control is installed, a setpoint will be
displayed on this screen. The setpoint can
be changed with the correct password.
REGENERATION TEMP
ACT 350°F SET 350°F
RETURN AIR TEMP
ACT 100°F SET 100°F
Function
4-12 l Oper a tion
Control Function Descriptions(continued)
When supplied for
central drying appli-
cations, this function
is not available.