EasyManua.ls Logo

Conair W Series - Page 51

Conair W Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
This screen shows the total run time in
hours that the dryer has been ran since it
was new. If the control board was changed
during the life of the dryer, this timer
will start over.
This is the CFM Monitor screen. It
displays the Process CFM and the Cool
down CFM. The Process CFM is
measured by a differential pressure
transducer across the inlet and the outlet of
the process blower. Since the Cool down
CFM is set with a mechanical orifice, it is
a fixed percentage of the measured process
reading. The CFM Monitor option must
be installed (see screen 75, page 4-28,
also see note on this page) for this to
appear
This screen shows if the aftercooler is
enabled. If the aftercooler is disabled,
there will be no setpoint for the Return Air
Temperature screen 5. The aftercooler
flow control option must be installed (see
screen 75, page 4-28, also see note on
this page) for this to appear
This screen shows if the control is opening
the solenoid valve. The aftercooler flow
control option must be installed (see
screen 75, page 4-28, also see note on
this page) for this to appear.
This screen shows if the control is opening
the precooler flow control solenoid valve.
The Precooler Flow Control option must
be installed (see screen 75, page 4-28,
also see note on this page) for this to
appear
Screen
SCREEN 17
SCREEN 20 (CFM Monitor
Option)
SCREEN 21 (Aftercooler Flow
Control Option)
SCREEN 21 (Aftercooler Flow
Control Option)
SCREEN 21 (Precooler Flow
Control Option)
TOTAL RUN HOURS
1250
PROCESS CFM 1600
Function
AFTERCOOLER
ENABLED
Operatio n l 4-15
4
Operation
Control Function Descriptions(continued)
When configured as a
central dryer, there is no
process heater in the
system. Therefore, any
function associated with
the process heater is not
available for central
dryer configurations.
Central
PRECOOLER
FLOW ON
AFTERCOOLER
FLOW ON
NOTE: Screens labeled 75 in
the display screen flow chart
on page 4-9 are various
option installation screens.

Table of Contents