2.3 general information
For your satisfaction, this appliance has been test-fired to assure its operation and quality.
EN
RATES AND EFFICIENCIES
CB36
CX36-1
NG
P
NG
P
Altitude (FT)
0-4,500
0-4500
0-4,500
0-4,500
Max. Input (BTU/HR)
18,000
18,000
25,000
25,000
Min. Inlet Gas Supply
4.5" (11mb) w.c.
11" (27mb) w.c.
4.5" (11mb) w.c.
11" (27mb) w.c.
Pressure
Max. Inlet Gas Supply
13" (32mb) w.c.
13" (32mb) w.c.
13" (17mb) w.c.
13" (32mb) w.c.
Pressure
Manifold Pressure (Under
3.5" (9mb) w.c.
10" (25mb) w.c.
3.5" (9mb) w.c.
10" (25mb) w.c.
Flow Conditions)
MODEL DESIGNATIONS
FUEL TYPE
OPERATING SYSTEM
CB36NTR
NATURAL
MILLIVOLT
CB36NTRE
NATURAL
ELECTRONIC IGNITION
CB36PTR
PROPANE
MILLIVOLT
CB36PTRE
PROPANE
ELECTRONIC IGNITION
CX36NTR-1
NATURAL
MILLIVOLT
CX36NTRE-1
NATURAL
ELECTRONIC IGNITION
CX36PTR-1
PROPANE
MILLIVOLT
CX36PTRE-1
PROPANE
ELECTRONIC IGNITION
When the appliance is installed at elevations above 4,500 ft (1371m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating
shall be reduced at the rate of 4% for each additional 1,000 ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for
mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.
However, optional blower requires 110 volts.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to
be expected.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.