Dinverter
A
User Guide
Issue code: d2au9
76
Note
Parameters that are related to speed (eg. 0.01 Minimum
speed) actually control frequency. When making
adjustments, set the value at the frequency that will give
the required motor speed.
Type User value
Default value
No. Function Limitations Range
0.00 Security,
configuration,
saving
RW R Uni 0 ~ 999
0
Speed clamp
0.01 Minimum speed RW Uni 0 ~ [0.02] Hz
0
Set at the frequency that will give the required minimum motor speed.
0.02 Maximum speed RW Uni
0 ~ ULF Hz
50 (EUR)
60 (USA)
Set at the frequency that will give the required maximum motor speed.
Note that the output frequency of the Drive can exceed the value set in
0.02 due to the actions of slip compensation and current limiting.
If [0.02] is set below [0.01], [0.01] is automatically set at the new value of
0.02.