110
Other Parameters
Setting Range
Parameter Name
Description
IEEE1547-2018
Rule21
ISO-NE
Min
Default
Max
Min
Default
Max
Min
Default
Max
delay
Anti reflux(LCD)
LCD anti-
backflow
communication
delay
0
0
255
0
0
255
0
0
255
RapidShutdownEn
Fast Shutdown
Enable control
0: Disable
1: Enable
0
1
1
0
1
1
0
1
1
Note: Compatibility among the functions:
1. Once the grid voltage is lower than LVRT trigger voltage, i.e. when it is in
LVRT state, the following functions will be unavailable:
Anti-islanding, QU, PF(P), Q(P), PF Setting, reactive power setting, over
frequency derating, GFCI, Grid over frequency protection, Grid unbalance
protection, DCI protection.
2. Only one of the following four functions can be set as valid at one time: QU,
PF(P), PF Setting and reactive power setting.