WARNING:
All the installation and wiring connections must be performed by
qualified technical personnel. Disconnect the inverter from the PV
modules and the AC grid before maintaining or servicing the
equipment.
Risk of electric shock and fire. Use only with PV modules that
have a maximum system voltage of rating of 1000V
DC
or higher.
Electric shock Hazard. The DC conductors of this photovoltaic
system are normally ungrounded but will become intermittently
grounded without indication when the inverter performs the PV
array isolation measurement.
Shock Hazard. The inverter is energized from both AC and DC
sources. Disconnect all energy sources before servicing.
For continued protection against risk of fire, replace only with same
type and ratings of fuse.
DANGER:
Disconnect the inverter from the AC grid and PV modules before
removing covers or opening the equipment. Wait at least 5 minutes
after disconnecting from the DC and AC sources before servicing or
maintaining the inverter. Ensure hazardous high voltage and energy
inside the inverter has been discharged prior to servicing.
NOTICE:
The inverters are designed to only interconnect with an AC power
source as part of the public electric utility grid. Do not connect the
AC output of the inverters directly to any private electric utility power
equipment. The inverters are to be installed with floating or
ungrounded PV arrays only.
CAUTION:
The main enclosure of CPS SCA36/50/60KTL-DO/US-480 inverters
weigh approximately 56kg (123.5 pounds). The wirebox portion
weighs approximately 15kg (33 pounds).
Ensure the mounting bracket is properly installed before hanging
the inverter and wirebox on the bracket. A team of two is
recommended to lift and place the inverter and wirebox into
position.