126
Fault0130
(Bus over total
voltage)
1. Restart inverter by turning both AC and
DC switches OFF. Wait for 5 minutes
for all energy to discharge between
OFF and turn both switches ON
2. If inverter cannot clear fault, replace
inverter
Fault0150
(Open-loop self-
check failure)
1. Restart inverter by turning both AC and
DC switches OFF. Wait for 5 minutes for
all energy to discharge and turn both
switches ON
2. If inverter cannot clear fault, replace
inverter
WARNING:
All the installation and wiring connections should be performed by
qualified technical personnel. Disconnect the inverter from PV
modules and the AC supply before undertaking maintenance.
Do not operate or maintain the inverter until at least 5 minutes after
disconnecting all sources of DC and AC.