REFRIGERATION SYSTEM
The Refrigeration System is a single piece unit and is hermetically sealed. The
Model BevMAX Refresh Media 5800-6/3800-6 Refrigeration Units consist of a
Super 1/3 Horsepower Compressor, with a single fin and tube style condensing
unit with one Condenser Fan, Condensation overflow Pan with Soakers,
Evaporator, and Evaporator Fan. . The Model BevMax Refresh 6 5800-6HC/3800-
6HC are charged with R290 refrigerant. Both units will be clearly labeled to assist
in identifying the refrigerant used The Refrigeration Unit is located behind the
Refrigeration Unit cover panels, mounted in the bottom of the Machine. This unit
is designed for easy removal and replacement from the front of the Vender as a
complete assembly. An electronic Encapsulated Temperature Sensor regulates
the Machine temperature. The probe of the Temperature Sensor is attached to
the Evaporator Coils and reads the temperature of air being pulled to the
Evaporator Coil.
REFRIGERATION DECK CLAMP ASSEMBLY
The Refrigeration Deck Clamp Assembly is located on the left side of the Cabinet base plate. Its
purpose is to secure the Refrigeration System tight against the vertical base plate for
refrigerated air flow in to the Cabinet. A 7/16” wrench or socket is needed to adjust the bolt.
The Refrigeration Unit also has a locating pin on the bottom of the Refrigeration Unit base plate
to ensure alignment for Refrigeration gasket seal to the vertical base plate.
WIRING notes:
The Vender wire harnessing has been reduced and is less complex. This improves wire routingthin the Service
Door and the Service and Refrigerated Compartments of the Machine.
Simplified Harnessing to all 5 Peripheral Boards with easily identified color coding.
RS 485 Communication Harness A common signal line white wire
RS 485 Communication Harness B common signal line blue wire
24VDC Harness red/green wire
5VDC Harness yellow wire