Page 21 of 57
Major Component Description
AC DISTRIBUTION BOX
BevMAX Refresh Media 5800-6/3800-6 & 5800-6HC/3800-6HC
120 VAC and 230VAC Machines
Main Power Switch or Power Supply Cord (A)
Interrupts hot and neutral side of incoming AC Power to all components in Machine
from the electrical outlet.
8 Pin JST Connector (B)
Provides AC power in to the OMRON Power Supply, Evaporator Fan, and
Refrigeration Unit (includes Condenser Fan and Defrost Control) from the AC
Distribution Box.
4 Pin Molex Connector (C)
Provides 24VDC in to AC Distribution Box to the Environmental Board from the
OMRON Power Supply.
24 Pin Molex Connector (D)
Provides 24VDC out to the Media Atlas H Board, it distributes 24VDC to the Port
Board, 24VDC and 5VDC to the Cup Motor Board, Cabinet X Motor Control Board, Y
Motor Board, and 3.3VDC to the Encapsulated Temp Sensor.
3 Amp 24VDC Circuit Breakers (2) (E)
Protect the 24VDC from the OMRON Power Supply. One is for the Cabinet electronics and the other is for
the Door electronics.
OMRON Power Supply 24V 150W
BevMAX Refresh Media 5800-6/3800-6 & 5800-6HC/3800-6HC
120 VAC and 230VAC Machines
5 Pin JST Connector (F)
Provides AC power in to the OMRON Power Supply from the AC Distribution Box.
6 Pin JST Connector (G)
Provides 24VDC out to AC Distribution Box Environmental Board from the OMRON
Power Supply.
Door Switch Bracket Assembly Switches
BevMAX Refresh Media 5800-6/3800-6 & 5800-6HC/3800-6HC
120 VAC and 230VAC Machines
Motor Power Interrupt Switch - Left Door Switch
3 Amp/24VDC – for XY Motor Circuits, Port Door Motor Circuit, and Picker Motor Circuit.
Service Door Switch - Right Door Switch
3 Amp/5VDC – for the Media Atlas H Board Service Switch input Circuit.