REFRIGERATION SYSTEM TROUBLESHOOTING FLOW CHARTS
ICE / FROST ON EVAPORATOR
CONDENSATE ON OUTSIDE OF PRODUCT DOOR
COMPRESSOR WILL NOT STOP
Move Machine.
Move Machine.
Machine in direct
sunlight or near
heat source.
Machine in
location with
humidity above
65%.
Check Product Door seal &
Harness openings in Cabinet.
Air leak.
Clear Drain from Molded Evaporator
Box to the Condensate Pan.
Check Product Door seal & Harness
Ports in Cabinet.
Ice / frost on
Evaporator.
Condensate Drain
plugged.
Air leak.
Verify Temp Sensor is plugged
in. Replace Temp. Sensor.
Compressor will
not stop.
Defective
Environmental
Board in AC
Distribution Box.
Replace Environmental Board.
Defective
Encapsulated
Temp. Sensor.
Check location of vender.