8
5. Min. No.
0000
0000-9999 (the min. serial no. of the receipt)
6. Max.No.
0000
0000-9999 (the max. serial no. of the receipt)
7.E-Barcode
ABCD
A=1, connect with the Guanghua e-scale, model
DS-788.
A=0, connect with the electronic instrumentation,
such as pricing.
A=4, connect with the electronic instrumentation,
such as weight.
CD is the e-scale barcode signs. Setting range
20-29.
8.Backlight
X00Y
X≠0, the machine has backlight.
X=0, close backlight.
Y is the time of closing backlight.
Y=0, the machine do not close the backlight.
(Its dard for the LCD screen if Y=0)
9.Decimal
XYZK
X—number of digits: 0-4
Y---fraction control: round off=0, cut off<5, round
up>5
Z---restriction (0,1) last amount digit: 0 digit: Z0,
1 digit: Z=0
K--- rounding when restriction: fraction cut off=0,
get integer of cash after fraction round up=1,
get integer of fraction after round off=2
10.S/C rate
0000
Service charge rate setting. Input 0500 means
this PLU add 5% service charge.
11. DCT rate
0000
Discount rate setting. Input 9500 means 5%
discount.
12.Sales set
000D
D=1, PLU adds service charge automatic.
D=2, the machine give the reduction automatic.
13.COM1
AB0D
A- Setup the print font of the external printer.
B- Setup the print method of the external printer.
D- Setup the external printer model.
(Please make sure the baud rate is 9600 when
use COM1 for communication)
14.COM2
000D
Same to 13.
15&16.
Reserved
0000
17. Reset
Rep.
A00D
A=0, do not reset the serial no. after clear the
e-journal information.
A=1, reset the receipt serial no. after clear the
financial report.