EasyManua.ls Logo

Crow PowerWave-16 - Programming User Codes

Crow PowerWave-16
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 17
TO EXIT PROGRAM MODES
To exit program modes when you have finished programming:
Press <PROGRAM> - <ENTER>
Program light goes out
The panel is now back in normal Run Mode, any program changes you have made will have replaced previous
values and be in effect.
Note: During programming Tampers and 24 hour alarms are disabled which allows quiet access to the panel,
detectors and satellite siren units etc. On exiting program mode, all inputs are scanned and if any tampers or 24Hr
alarms are present an activation will occur.
PROGRAMMING USER CODES
P1E to P50 E
There are 51 codes available in the PowerWave16 , 50 user codes and 1 install code. The user codes are located
in addresses 1-50. By default, Code 1 is the Master Code because it has full access to enter program mode. Other
user codes can be programmed as master codes also if required. The Installer code is stored at address 249 and is
used to move from Client Program mode up to Installer Program mode.
Codes 1-50 may be varied in length from 1 to 6 digits. Code 249 must be 3-6 digits.
To program a User Code you must first be in client or installer program mode, then select the address from
1-50. (If there is already a code programmed at this address, it will be flashed back to you)
NOTE: Not all User Codes may have the ability to access Client Program Mode. The installer can restrict access to
Users so that they have no access to Client Mode or they can have access to change only their code or they may
have access to change all User codes as defined at addresses P101-P150.
To change User code 1 from the default setting of 1,2,3 to 9,8,7,6 you would enter the following data at the keypad.
P 1 E
(Old code is flashed back at the keypad, in this case it will be 1,2,3)
Then 9876 E
3 beeps - program light On or Flashing
The new code will now be displayed back using the keypad LED’s
To program a new user code for User 5 you would enter the following;
P 5 E
(If a code was there it would be displayed if not the display will be blank )
Then 567 E
3 beeps - program light On or Flashing
The new code will now be displayed back using the keypad LED’s
Note: Where there are multiple options at one address, options 0 & 9 have been reserved. Entering a 0 at
the address will turn all options off whereas entering a 9 will turn all options on.
User 1 Code
1
2 3