ENABLING VARIOUS DIALLER REPORTING OPTIONS
B
P315E 1-8E Various Reporting Options B (Default = 1,2,3) On = Send, Off = Don’t Send
1 = Report Panic Alarms via Dialler
2 = Report Fire Alarms via Dialler
3 = Report Medical Alarms via Dialler
4 = Report 24 Hour alarms for Voice/Domestic/Pager Mode
KEYPAD LISTEN-IN OPTIONS
P312E Keypad Listen-in Options (Default = 1,7)
1 = Enabled During Dialling in Disarm State only
2 = Enabled During Dialling in Armed State only
3 = Enabled During Dialling in Monitor Mode State only
4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Monitor Mode State only
7 = Listen-in Enabled when the panel answers a call
8 = Enabled at All Times
OUTPUT #1 LISTEN-IN OPTIONS
P313E Output # 1 Listen-in Options (Default = None)
1 = Enabled During Dialling in Disarm State only
2 = Enabled During Dialling in Armed State only
3 = Enabled During Dialling in Monitor Mode State only
4 = Enabled Throughout the call in Disarm State only
5 = Enabled Throughout the call in Armed State only
6 = Enabled Throughout the call in Monitor Mode State only
7 = Listen-in Enabled when the panel answers a call
8 = Enabled at All Times
AUTO-ANSWER RING COUNT
P369E 1-99E Auto-Answer Rings - This option defines the number of rings before the panel will auto-answer
the incoming call. (Default = 8)
MAINS FAIL REPORT DELAY
P559E 1-999E Mains Fail Report Delay - When there is a m a i n s
supply failure, the mains must fail for l o n g e r than the
programmed delay at this address before the panel will report the alarm. A
value from 1-999 seconds can be
programmed as the delay. A value of 0 will result in an
instant report of mains failure.
(Default = 600 seconds)
ZONE ALARM REPORT DELAY
P560E 0-999E Report Delay on Zones - This delay pauses the zone reporting of alarms via the panel for
the programmed period (0 = No delay or 1-999 seconds). If the alarm is reset before this
delay expires no alarms will be reported.
Zone Reporting De