Page 42
This block of addresses is used to map radio users to outputs in conjunction with P681E - P700E. All output
modifiers such as reset timers and lock out functions are maintained and will determine the behaviour of the
assigned output.
]
P701E 1-8E Radio user #1 to output 1-8 - Where options 1-8 represent outputs 1-8
P702E 1-8E Radio user #2 to output 1-8 - Where options 1-8 represent outputs 1-8
P703E 1-8E Radio user #3 to output 1-8 - Where options 1-8 represent outputs 1-8
P704E 1-8E
Radio user #4 to output 1-8
- Where options 1-8 represent outputs 1-8
P705E 1-8E Radio user #5 to output 1-8 - Where options 1-8 represent outputs 1-8
P706E 1-8E Radio user #6 to output 1-8 - Where options 1-8 represent outputs 1-8
P707E 1-8E
Radio user #7 to output 1-8
- Where options 1-8 represent outputs 1-8
P708E 1-8E Radio user #8 to output 1-8 - Where options 1-8 represent outputs 1-8
P709E 1-8E Radio user #9 to output 1-8 - Where options 1-8 represent outputs 1-8
P710E 1-8E
Radio user #10 to output 1-8
- Where options 1-8 represent outputs 1-8
P711E 1-8E Radio user #11 to output 1-8 - Where options 1-8 represent outputs 1-8
P712E 1-8E Radio user #12 to output 1-8 - Where options 1-8 represent outputs 1-8
P713E 1-8E Radio user #13 to output 1-8 - Where options 1-8 represent outputs 1-8
P714E 1-8E
Radio user #14 to output 1-8
- Where options 1-8 represent outputs 1-8
P715E 1-8E Radio user #15 to output 1-8 - Where options 1-8 represent outputs 1-8
P716E 1-8E Radio user #16 to output 1-8 - Where options 1-8 represent outputs 1-8
P717E 1-8E
Radio user #17 to output 1-8
- Where options 1-8 represent outputs 1-8
P718E 1-8E Radio user #18 to output 1-8 - Where options 1-8 represent outputs 1-8
P719E 1-8E Radio user #19 to output 1-8 - Where options 1-8 represent outputs 1-8
P720E 1-8E
Radio user #20 to output 1-8
- Where options 1-8 represent outputs 1-8
PROGRAMMING TIME ZONES
This block of addresses is used to define the time zones used by outputs, users and the Auto Arm/Disarm feature.
Time zones require a start and a finish time with the effective window as the difference between start and finish.
For this reason the finish time value must be higher than the start value. All times are set in 24 hour clock format.
P791E 1-8E
TZ1 days of the week
- Where 1-7 represent the days of the week which the time zone
will operate where 1 = Sunday, 2 = Monday etc. A value of 8 at this address will invert
the TZ function so that instead of being effective during the window created by the start
and finish times, the TZ is effective during the times outside the window set by the start
and finish times.
P792E 0000 - 2359E TZ1 Start time - This is the time when the TZ will start. Use 24 hour format. (HHMM)
P793E 0000 - 2359E
TZ1 Finish time
- This is the time of day when the TZ will finish. The finish time must
be greater than the start time. Use 24 hour format. (HHMM)
There are 8 time zones available and they occupy addresses P791E to
P814E. Each time zone requires 3 addresses to be assigned.
P791E TZ1 Day of the week P803E T Z 5 D a y
- - - - - - - -
Daylight saving sta
0
Misc system flag