USER CODE TIME CONTROL
P151E-P200E
Users codes may have Time Zones assigned to control their operation. These Time Zones determine when a
particular user code will work. Addresses P151E - P200E are used to map the user code to the required Time
Zones. The actual Time Zone parameters are defined at addresses P791E - P814E.
More than one time zones can be assigned to a code. The time zones are numbered 1-8 and are selected by the
numeric buttons 1-8 on the keypad. A value of zero (0) entered at any of these addresses is fixed as 24 hour seven
day access and is the default time zone for all 50 user codes.
P151E TZ E Where TZ represents any Time Zone from 1-8 valid for User Code #1
P152E TZ E Where TZ represents any Time Zone from 1-8 valid for User Code #2
P200E TZ E
Where TZ represents any Time Zone from 1-8 valid for User Code #50
NOTE: The ability to assign more than one Time Zone to each user allows for different time based controls
for different days of the week.
INSTALLER CODE
P249E
This code is used to enter full Installer Program mode (Program light flashing) from Client Program mode (Program
light steady) The default installer code is 000000. To change this code you Must first be in Installer Program Mode
then enter your new installer code at the P249E address. The new code will be flashed back to you automatically.
The Installer Code may vary from 3-6 digits in length.
If the alarm is Unset then the Installer Code can gain access directly to Installer Program Mode provided Option 6 at
address P310E is on. If any partition is armed then the installer code can only gain access to Installer Program Mode
from Client Program Mode.
PROGRAMMING OUTPUT OPTIONS
P201E-P208E
This block of addresses (P201E - P208E) is used to map output modifiers to each of the 8 outputs available on the
PW16. The optional 4 way relay output board (OUTPUTX4) can be configured to follow the program options for any
of the 8 outputs, the 4 relays can be assigned as output 1 or 5, 2 or 6, 3 or 7 & 4 or 8.
P201E 1E Invert output #1 - Default off
2E Flash output #1 - Default off
3E Single pulse to output #1 - Default off
4E Lockout output #1 once reset
- Default off
5E Output mapped to Remote Command Control - Default off
6E Output mapped to local Command Control - Default off
7E Day zones linked to pulse timer
- Default off
8E Output pulses on a 24 hour zone alarm - Default off
User 1 Time Zone
- - - - - - - -
Installer Code
000000
Out 1 Option A
- - - - - - - -