Page 56
AREA ARM/DISARM REPORTING OPTIONS
P289E 1-8E
Area “A” Reporting Options
- Default 1,2
P389E 1-8E
Area "B" Reporting Options - Default 1,2
P489E 1-8E
Area "C" Reporting Options
- Default 1,2
1 = Send Arm/Disarm
2 = Send Stay Mode Arm/Disarm
3 = Send Disarm only after activations
4 = Send Stay Disarm only after activations
5 = Send Arm at the end of the exit delay
6 = Send all zone restores when disarmed
7 = Spare
8 = Spare
Option 1 Send Arm / Disarm - If this option is on, the dialler will report Area "A" arms and disarms.
Option 2 Send Stay Mode Arm / Disarm - If this option is on, the dialler will report Area "A" stay mode
arms and disarms.
Option 3 Send Disarm only after activation - If this option is on, the dialler will report an Area A disarm
following an alarm activation only. This option is often used in conjunction with alarm only
reporting and stops the normal arm/disarm signals from being sent. If this option is on it will
override the option 1 setting.
Option 4 Send Stay Mode Disarm only after activation - If this option is on, the dialler will report an
Area A Stay Mode disarm following an alarm activation only. This option is often used in
conjunction with alarm only reporting and stops the normal Stay Mode arm/disarm signals from
being sent. If this option is on it will override the option 2 setting.
Option 5 Send Arm at the end of the exit delay - If the LED is Off, the dialler will report an Arm
immediately the panel is armed. If the LED is On, the Arm report is sent at the expiry of the exit
delay.
Option 6 Send all zone restores when disarmed - If this option is Off, the dialler will send all zone
restores as they occur. If the option is On, the dialler will send all zone restores only when the
panel is disarmed. If the option is On, only one restore will be sent for each zone that activates
regardless of whether the zones can send multiple alarm reports.
Option 7 Spare
Option 8
Spare
ENABLING VARIOUS DIALLER REPORTING OPTIONS A
P314E
1-8E
Various Reporting Options A (Default = all)
On = Send, Off = Don’t Send
1 = Report Duress via Dialler
2 = Report Mains or 12V fuse (F1 & F2 on control board) Failure via Dialler
3 = Report System Battery Low via Dialler
4 = Report Radio Battery Low via Dialler
5 = Report System Tamper via Dialler
6 = Report Telephone Line Failure via Dialler
7 = Report Supervised Radio alarm via Dialler
8 = Report Zone Inactivity Timeout via Dialler
A Phone Options
1 2 - - - - - -
1 2 - 4 5 6 7 8
Report Options A