Page 58
Character LED KP Special
Function Key
Displayed as
On 8LED KP
Displayed as
On 16LED KP
Displayed as
On Alert KP
LCD KP Special
Function Key
Displayed as
On LCD KP
“B”
PANIC Line 11 Ready “Control” ”2” B
“C”
MEMORY Memory 12 System “Control” ”3” C
“D”
CONTROL Control 13 Trouble “Control” ”4” D
“E”
ARM Armed 14 Ready/System “Control” ”5” E
“F”
STAY Bypass 15 Ready/Trouble “Control” ”6” F
This delay pauses the reporting of zone alarms for all reporting formats. This delay can be used to prevent false
alarms from reporting if the alarm is cancelled before this delay expires.
UPLOAD/DOWNLOAD SECURITY OPTIONS
P828E
XXXXXXXX
. Up to 8 digit security code for upload/download.
P835E Answer incoming call - provided a user with option 5 set
(P101-P150) enters in P835E while in c l i e n t
program mode and the telephone line is currently ringing the panel will
answer the
incoming call and initiate an upload/download connection.
PROGRAMMING 4+2 SPECIAL CHARACTERS
When programming 4+2 event codes (see pages 76-80) you can enter in digits 1234567890 plus the following
special characters BCDEF. If you enter in a value of “00” or press the “Exclude” button after a 4+2 program address
then the appropriate option will not report via the dialler e.g. P865E-00-E or P865E-exclude-E will disable the
keypad panic alarm reporting function in 4+2 mode. The “Control” “0” keys are used to remove an entry when using
the LCD keypad. The 4+2 event codes must be 2 digits but they can be in any order e.g.;
P865E-01
-E, or P865E-C6-E, or P865E-4F-E, etc.
In the above examples, the letters are programmed using the special function keys listed in the table below. When
displaying the address back at the keypad the associated keypad LED’s are also listed against the special letters B-
F. (NOTE: A value of “0” in 4+2 will be transmitted as 10 pulses to the monitoring station).
COMMON CONTACT ID CODES
Medical Alarm 100 Low Temperature 159
Medical Pendant 101 High Temperature 158
Fire Alarm 110 Refrigeration Alarm 152
Smoke Detector 111 Water Leakage 154
Heat Detector 114 Gas Detector 151
Manual Call Point 115
Duct Detector 116
Silent Panic 122
Security Code