PROGRAMMING YOUR PowerWave
ACCESS TO INSTALLER PROGRAMMING ON POWER UP
When power is applied to the controller for the first time, with the panel tamper input open and none of the
Areas either fully Armed or in Stay mode
, the panel will inhibit tamper alarms and ready the panel to enter
PROGRAM Mode( unless the Installer Lock-out option P210E7E has previously been enabled). At this point you
can go to any keypad which is connected to the panel and;
Press –”
PROGRAM”-”ENTER”
which will automatically put that keypad into full Program mode, Program LED Flashing.(NOTE:Only one keypad
can be in Program mode at any time)
ACCESS TO PROGRAM MODES FROM RUN MODE
Before you can enter program mode from the normal Run Mode, the panel must be unset and not in stay mode.
Then;
Press <PROGRAM> - <Code 1(or Master Code)> - <ENTER>
Program light steady
Note: Default Master Code (Code 1) is 1,2,3
You are now in Client Program Mode. When you are in Client programming mode you have access to program
addresses P1E to P24E (user code programming). To Enter Installer Program Mode from Client Program Mode;
Press <PROGRAM> - <Install Code> - <ENTER>
Program light flashing
Note: Default Install Code (P99) is 0,0,0,0,0,0
By default the installer can go directly to Installer Program Mode from Normal Run mode provided No Areas are
Armed or in Stay Mode. The Installer Mode direct option can be disabled at address P210E Option 7.
HOW TO PROGRAM
The programming sequence always follows this pattern;
<PROGRAM> - <1,2 or 3 digit address> - <ENTER>
3 short beeps if OK - 1 long beep if error
The leds will display current value or status
Enter the new value or option
<New Value> - <
ENTER
>
3 short beeps if OK - 1 long beep if error
An example of programming is shown below. Here we are programming User Code 23 (P23E) with the code
number of 2580.
P 23 E 2,5,8,0 E
In this example the <P> represents the PROGRAM key, <23> represents the actual program address, 2580 is the
data and <E> represents the ENTER key.
TO CLEAR PROGRAM INFORMATION
(From Install Mode Only)
There are multiple options available for clearing program information (Reset to
defaults). These are detailed on page 38.
e.g.To reset User Codes 1-24 (P 720E)
Press <PROGRAM> - 720 - <ENTER>
3 beeps - Program light flashing
After resetting the various defaults, all options associated with that function (eg User Code Defaults P720E) will be
set to the default values shown in the Program Summary at the rear of this manual. The default settings have been
chosen to simplify the installation process by minimising the amount of programming necessary to get the system
fully functional.