Page 50
Option 7 Auto-Detect Modem Format - The panel can connect using Bell103 or V21 formats when
performing upload/download connections. If this option is On the panel generates the V21
tones first and if no connection is established it then generates the Bell103 tones. If this option
is turned off then the format is fixed by the selection made at option 8.
Option 8
Force Bell103/V21 Modem Format -
If option 7 above is turned off then the modem format to
be used for upload/download is specified here. If this option is Off the format is Bell103, On is
V21.
COMMUNICATOR REPORTING
SCENARIOS
COMMUNICATOR REPORTING SCENARIOS
In order to provide you with the best flexibility when reporting alarms we have developed a unique system called
"Reporting Scenarios". The Scenarios define what action is taken by the panel for each alarm event, e.g. alternate
between numbers 1&2 until one is kissed-off or dual report to numbers 1&2 until both kissed-off. There are four
individual scenarios available each with up to 16 possible steps. The Scenarios consist of a string of digits that
define the reporting action to be taken by the panel. The digits in a Scenario are pre-defined. What the various
digits are and their meaning are listed below.
Scenario Options;
1 = Call Telephone Number 1 6 = Call Telephone Number 6
2 = Call Telephone Number 2 7 = Return to step 1 until all numbers are kissed-off
3 = Call Telephone Number 3 8 = Return to previous step if not kissed-off
4 = Call Telephone Number 4 9 = Stop if kissed-off, if not proceed to next step
5 = Call Telephone Number 5
Example 1 (alternate dialling) 1 9 2 9 7
In this example we have defined a scenario with five steps as follows.
Step 1 - Dial Ph # 1.
Step 2 - If not Kissed-off (defined by the 9) continue to next step
Step 3
- Dial Ph # 2
Step 4 - If not Kissed-off (defined by the 9)
continue to next step
Step 5 - If not kissed-off return to Ph #1
(the 7 causes a return to the start)
This process is repeated until kissed-off or the maximum number of
dialling attempts have been reached for this scenario.
Example 2 (dual reporting) 172 7
In this example we have defined a scenario with four steps as follows.
Step 1
- Dial Ph # 1.
Step 2 - If not Kissed-off return to Ph # 1 (the 7 causes a return to the start).
When kissed-off or the maximum re-tries reached, move forward to the next step.
Step 3 - Dial Ph # 2
Character LED KP Button
Displayed as
On
8LED KP
Displayed as
On
16LED KP
Displayed as
On
Alert KP
LCD KP Button
Displayed as
On
LCD KP
2.5 sec pause
CONTROL Control 13 Trouble “Control” ”2” -
* Character
MEMORY Memory 12 System “Control” ”3” *
# Character
PANIC Line 11 Ready “Control” ”4” #
Wait for 2nd
ARM Armed 14 Ready/System “Control” ”5” W
5 sec pause
STAY Bypass 15 Ready/Trouble “Control” ”6” =
Phone Number 1
Phone 1 Mode
2