ON MESSAGE FOR ARM/DISARM STATUS MESSAGES
If the ON message number is left blank i.e. “0”, the panel will assume that there is no voice message for this
Command Control function and revert to the DTMF board tones e.g. One long tone for ON and three short beeps
for OFF.
P777E
code E Area “A” ON message number - This is the message number where the Area “A” armed
message starts. The Area “A” disarmed message must be the next message.
P778E
code E
Area “B” ON message number
- This is the message number where the Area “B” armed
message starts. The Area “A” disarmed message must be the next message.
P779E
code E
Area “C” ON message number
- This is the message number where the Area “C” armed
message starts. The Area “A” disarmed message must be the next message.
ON MESSAGE FOR OUTPUT STATUS MESSAGES
If the ON message number is left blank i.e. “0”, the panel will assume that there is no voice message for this
Command Control function and revert to the DTMF board tones e.g. One long tone for ON and three short beeps
for OFF.
P781E code E Output #1 ON message number - This is the message number where the Output #1 ON
message starts. The Output #1 OFF message must be the next message.
P782E code E Output #2 ON message number - This is the message number where the Output #2 ON
message starts. The Output #2 OFF message must be the next message.
P783E code E
Output #3 ON message number
- This is the message number where the Output #3 ON
message starts. The Output #3 OFF message must be the next message.
P784E code E
Output #4 ON message number
- This is the message number where the Output #4 ON
message starts. The Output #4 OFF message must be the next message.
P785E code E Output #5 ON message number - This is the message number where the Output #5 ON
message starts. The Output #5 OFF message must be the next message.
P786E code E Output #6 ON message number - This is the message number where the Output #6 ON
message starts. The Output #6 OFF message must be the next message.
P787E code E Output #7 ON message number - This is the message number where the Output #7 ON
message starts. The Output #7 OFF message must be the next message.
P788E code E
Output #8 ON message number
- This is the message number where the Output #8 ON
message starts. The Output #8 OFF message must be the next message.
EXAMPLE OF HOW THE COMMAND CONTROL MESSAGE ADDRESSING WORKS.
We have assumed that there are 3 voice alarm reporting messages programmed for warning of alarm conditions
via the telephone. These messages could be;
Message #1 “Burglar alarm at Acme Building Products”
Message #2 “ Fire alarm at Acme Building Products”
Message #3 “Panic alarm at Acme Building Products”.
Next, we require arm/disarm capability for Areas A & B plus we need to be able to turn Outputs 5 & 8 On and Off
remotely. The messages could be set-up as follows;