Page 61
Programming Output Options
P201E Output #1 Primary options - Default none 1 = Invert Page 19
P202E Output #2 Primary options - Default none 2 = Flashing Page 19
P203E Output #3 Primary options - Default none 3 = Single pulse Page 19
P204E
Output #4 Primary options - Default none 4 = One Shot (lock-out) Page 19
P205E Output #5 Primary options - Default none 5 = DTMF cmd remote control Page 19
P206E Output #6 Primary options - Default none 6 = Local command control Page 19
P207E
Output #7 Primary options - Default none 7 = Day zone linked to pulse timer Page 19
P208E Output #8 Primary options - Default none 8 = Pulsed 24 Hour alarm Page 19
P211E Output #1 Expanded options - Default 1,3,4,5 P211E-P218E OPTIONS Page 20
P212E Output #2 Expanded options - Default 1,3,4,5 1 = Keypad panic to output Page 20
P213E
Output #3 Expanded options - Default 1,3,4,5 2 = Keypad fire to output Page 20
P214E Output #4 Expanded options - Default 1,3,4,5 3 = Keypad medical to output Page 20
P215E Output #5 Expanded options - Default 1,3,4,5 4 = Duress Alarm to output Page 20
P216E
Output #6 Expanded options - Default 1,3,4,5 5 = Keypad tamper to output Page 20
P217E Output #7 Expanded options - Default 1,3,4,5 6 = Radio key panic to output Page 20
P218E Output #8 Expanded options - Default 1,3,4,5 7 = 24 hour alarms Page 20
8 = 24 hour fire alarms
P221E
Output #1 Expanded options 2 - Default 1,3,4,5
P221E-P228E OPTIONS
Page 21
P222E Output #2 Expanded options 2 - Default 1,3,4,5 1 = Zone tampers to output Page 21
P223E Output #3 Expanded options 2 - Default 1,3,4,5 2 = Cabinet tamper to output Page 21
P224E
Output #4 Expanded options 2 - Default 1,3,4,5 3 = Mains fail to output Page 21
P225E Output #5 Expanded options 2 - Default 1,3,4,5 4 = Battery low to output Page 21
P226E Output #6 Expanded options 2 - Default 1,3,4,5 5 = Phone Line failure Page 21
P227E Output #7 Expanded options 2 - Default 1,3,4,5 6 = Failure to get kiss-off Page 21
P228E
Output #8 Expanded options 2 - Default 1,3,4,5 7 = Automatic pulse every 5 sec. Page 21
8 = 24 Hour alarm reset pulse
P231E
Output #1 Automatic on / off time zones - Default 0 (never) Page 21
P232E Output #2 Automatic on / off time zones - Default 0 (never) Page 21
P233E Output #3 Automatic on / off time zones - Default 0 (never) Page 21
P234E
Output #4 Automatic on / off time zones - Default 0 (never) Page 21
P235E Output #5 Automatic on / off time zones - Default 0 (never) Page 21
P236E Output #6 Automatic on / off time zones - Default 0 (never) Page 21
P237E
Output #7 Automatic on / off time zones - Default 0 (never) Page 21
P238E Output #8 Automatic on / off time zones - Default 0 (never) Page 21
P241E Output #1 Enable time zones - Default 0 (always) Page 22
P242E Output #2 Enable time zones - Default 0 (always) Page 22
P243E
Output #3 Enable time zones - Default 0 (always) Page 22
P244E Output #4 Enable time zones - Default 0 (always) Page 22
P245E Output #5 Enable time zones - Default 0 (always) Page 22
P246E
Output #6 Enable time zones - Default 0 (always) Page 22
P247E Output #7 Enable time zones - Default 0 (always) Page 22
P248E Output #8 Enable time zones - Default 0 (always) Page 22
P249E Installer Code - Default 000000 - must be more than 3 digits long Page 19
Programming Keypad Options
P250E
Keypads assigned to Area "A" - Default 1-8 Page 22
P251E Keypads assigned to Area "B" - Default none Page 22
P252E Keypads assigned to Area "C" - Default none Page 22
P253E Keypads with permission to set - Default 1-8 Page 22
P254E
Keypads with permission to Monitor - Default 1-8 Page 22
P255E Keypads with permission to use control function - Default 1-8 Page 23
P256E Keypads with permission to exclude zones - Default 1-8 Page 23
P257E
Keypads (LED) with Panic Button enabled - Default 1-8 Page 23
P258E Keypads (LED) with Delayed Panic Button enabled - Default 1-8 Page 23