Error 6 - Membrane Fault (Stuck Key)
Cause:
Membrane is showing a key constantly activated (noticed at power-up.)
Service:
• Check the membrane and thumb controls for signs of fatigue, cracking, or possible moisture intrusion.
• Ensure the membrane connector is fully seated.
• Inspect the membrane cable for cuts, pinches, and all leads are fully inserted in their connectors.
• Replace the membrane and/or the thumb control switches.
Key list
Left and Right controls
DescriptionKey
Incline Down1
Incline Up2
Resistance Down3
Resistance Up4
Main controls
DescriptionKey
Volume Up5
Volume Down6
Channel Up or Next7
Channel Down or Previous8
STOP9
Fan10
700 series membrane
Page 46 of 202
Cybex 772A, 772AT Arc Trainer Part Number