Error 8: Approaching Over-Temperature
Cause:
Drive is reporting a temperature of 100+°C
Service:
If Error 8 is alone in the log, or with other Error 8’s, then the product may be getting warm simply from
excessive high-powered use.
Verify there are no shorts in the console cable from the LCB up to the display itself.
Verify the brake and LCB are free from debris and accumulated dust.
Vacuum the inside of the unit and ensure all ventilation is clear.
Test the brake coil for potentially shorted windings.
Replace the LCB first if the brake tests out normal and use looks normal.
Replace the brake.