Error 9: MCC Watchdog triggered
Cause:
A software task has failed, causing a delay in the routine running of the code. If the delay is long enough,
a hardware timer in the processor will re-boot the processor. When the processor comes up, it will
communicate what caused the reset (watchdog vs. normal power reset.) Watchdog resets are logged
as Error 9. Power resets are not logged.
Service:
Possible causes of this watchdog error include ESD (Static Electricity) or hardware failures in the display
and/or handset board.
• Software issue, update software
• ESD event (inquire on the user as to what caused the issue)
• Check the console cable for damage
• Reprogram or replace the MCC if the problem persists