Error 35: LCB Latched On / Can’t shut down
Cause:
The drive is powered off of the generator yet it senses it is on battery, or some other internal LCB power
management has failed.
Service:
Lower Board needs servicing, re-programming, or replacement.
Flowchart: Error 35
Page 79 of 202