Error 38: Incline Timeout
Cause:
Incline is commanded to move yet the feedback indicates it has not reached the target within the allotted
timeframe.
Service:
Incline motor’s potentiometer is physically rotated out of position
Potentiometer is damaged or the gear drive to it is worn or spinning on the shaft
Incline is hitting the low limit (the motor case) or the high limit (the weld washer), caused by the
calibration to be off or corrupted
Fuse blown on controller or other controller hardware failure
Check wiring from incline motor to LCB for nicks, shorts, opens