Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 5
Page 3.3.8
Governor control not operating
Fly the airplane
1 - Continue the flight.
If Np < 1960 RPM :
Do not perform a go around
Do not use the reverse
In that case, the go-around performance and the reverse efficiency might be lower
than expected.
Repair before further flight.
End of procedure.
Excessive propeller rotation speed
Fly the airplane
1 - Reduce the power and the airplane speed to avoid propeller rotation speeds
higher than 2050 RPM.
Land as soon as possible
Do not perform a go around
In that case, the go-around may damage the gear reduction box and the reverse
efficiency might be lower than expected.
Repair before further flight.
End of procedure.