Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 5
Page 3.9.13
Total loss of electrical power
CAUTION
If no ESI-2000 key is pressed, the ESI-2000 will shut down
automatically within 5 minutes.
1 - Maintain airplane control.
2 - ESI-2000 Press any key within 5 minutes. . . . . . . . . . . . . . . . . . . . . . . . . . . .
To enable the use of ESI-2000 internal battery
3 - Use the ESI-2000 for
- attitude,
- airspeed and/or
- altitude
Fly the airplane
Land as soon as possible
NOTE
Airplane power is provided to the ESI-2000 display for normal operation.
Operation of the basic system is automatic. The system is powered ON while
airplane power is ON.
If airplane power is lost, the internal battery will provide power to the ESI-2000.
Press any key to allow the ESI-2000 to continue operation using the internal
battery.
End of procedure.