EasyManua.ls Logo

Dahua Mobile DVR Series - Alarm Output Port

Dahua Mobile DVR Series
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Figure 3-9
3.4.3 Alarm Output Port
Alarm output is on-off signal alarm output (NO). Please use additional power supplying for the
peripheral device.
To avoid overloading, please read the following relay parameters sheet carefully.
Relay Specification
Model: HFD23
Contact
Parameter
Contact mode
1Z
Contact resistance
100mΩ(0.1A 6VDC)
Contact material
AgNi+gold-plating
Contact
Load(Resistance)
AC 125V 0.5A /DC 30V 1A
Max switch voltage
AC 125V / DC 60V
Max switch current
2A
Max switch power
62.5VA/30W
Min allowed load
1mA 5V
Mechanical durability
1x10
7
(300/min)
Electric durability
1x10
5
(30/min)
Performance
Parameter
Insulation resistance
1000MΩ(500VDC)
Media
pressure
Between
loop and
contract
AC 1000V 1min
Between
separated
contact
AC 400V 1min
Operation time (Rated
voltage)
≤5ms
Release time (Rated
voltage)
≤5ms