293
Parameter Description
When one of the comparison objects is a spot, both the highest
temp and lowest temp is the average temp.
Alarm Condition
The condition to trigger the alarm, including higher, lower and
match.
Alarm temp
threshold
The temp to trigger the alarm. The range is 0-550.
Step 3 Click OK to complete the setting.
Step 4 After the settin, you can view the temp comparison results on the preview interface on the left of
the window.
4.6.3.3 Global
You can enable temperature switch, isotherm and color code.
After enabling the temperature switch, temp rule comes into effect and the preset temp rule is
displayed on the window.
The isotherm function is mainly used for the objects that need to be highlighted in the highlight
screen. The median temperature is taken as the reference, the upper limit temperature and lower
limit temperature as the floating range, and those above the lower limit temperature are represented
by bright colors, while those below the lower limit are shown as black and white.
When the color code is enabled, the corresponding color bar is displayed on the right side of the
monitoring interface to indicate the color change between the lowest temperature and the highest
temperature.
Step 1 Select Setup > Temperature Measurement > Global.
The Global interface is displayed. See Figure 4-55
Figure 4-55