SiENBE04-808_A Service Check Function
Service Diagnosis 100
3.2 ARC433 Series
Check Method 1 1. When the timer cancel button is held down for 5 seconds, “00” indication appears on the
temperature display section.
2. Press the timer cancel button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
Note: 1. A short beep “pi” and two consecutive beeps “pi pi” indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote control is left untouched for 60 seconds, it also returns to the normal mode.
No. Code No. Code No. Code
1 00 12 F6 23 A1
2 U4 13 C7 24 E1
3 L5 14 A3 25 UA
4 E6 15 H8 26 UH
5 H6 16 H9 27 P4
6 H0 17 C9 28 L3
7 A6 18 C4 29 L4
8 E7 19 C5 30 H7
9 U0 20 J3 31 U2
10 F3 21 J6 32 EA
11 A5 22 E5 33 AH
TIMER CANCEL button
(R11949)
< ARC433 Series >
SiENBE04-808_A.pdf 112 21/02/2011 13:20:01