Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B SiENBE04-808_A
229 Removal Procedure
3.4 Removal of Reactor / Partition Plate
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the reactor. Preparation
Remove the outer panels
according to the “Removal of
Outer Panels / Fan Motor”.
Remove the electrical box
according to the “Removal of
Electrical Box”.
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
(R11879)
Reactor
(R11880)
(R12273)
Partition plate