Daikin FTXS20G2V1B - Removal of Electrical Box

Daikin FTXS20G2V1B
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiENBE04-808_A Outdoor Unit - RK(X)S50G2V1B, ARXS50G2V1B
Removal Procedure 270
5.3 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Remove the 2 screws
of the shield plate.
Preparation
Remove the top panel and
the front panel according to
the “Removal of Outer
Panels”.
2
Slide the shield plate
upward to unfasten the
1 hook on the bottom
left, and then remove
the shield plate.
3
Disconnect the 2 power
supply cables and the 1
earth wire.
(R5266)
Shield
plate
(R5267)
(R5268)
Earth wire
SiENBE04-808_A.pdf 282 21/02/2011 13:20:23