EasyManua.ls Logo

Daikin FTXS20G2V1B - Removal of Electrical Box

Daikin FTXS20G2V1B
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiENBE04-808_A Outdoor Unit - RK(X)S20-35G2V1B, ARXS20-35G2V1B
Removal Procedure 192
2.2 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Disconnect the 2
connectors for the
reactor.
Preparation
Remove the panels and
disconnect the connector for
the fan motor according to
the “Removal of Outer
Panels / Fan Motor”.
2
Cut the clamps at 2
locations.
3
Disconnect the
connector for the
compressor [S30].
When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R9338)
(R9339)
(R9340)
[S30]
SiENBE04-808_A.pdf 204 21/02/2011 13:20:11