Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B SiENBE04-808_A
221 Removal Procedure
3.3 Removal of PCB
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the main PCB. You can remove the main
PCB when you disconnect
the lead wires on the
terminal board without
removing the electrical box.
1
Feature of the main
PCB
2
Remove the screw on
the terminal board.
3
Release the 2 earth
terminals.
(R11853)
(R11854)
Terminal
board
(R11855)
Earth
terminal
SiENBE04-808_A.pdf 233 21/02/2011 13:20:15